Skip to content
Server Security Center
KEVhigh7.2

CVE-2024-8957: PTZOptics PT30X-SDI/NDI Cameras OS Command Injection

PTZOptics PT30X-SDI/NDI Cameras · listed in the CISA catalog of actively exploited vulnerabilities since 2024-11-04.

CVSS v3.1 (CVE record)
7.2
high
EPSS (exploit probability, 30 days)
80%
higher than 99.6% of all CVEs
Added to CISA KEV
2024-11-04
US federal due date 2024-11-25
Automatable (CISA SSVC)
no
technical impact: total

CVE-2024-8957 explained

CVE-2024-8957 is an OS command injection vulnerability in PTZOptics PT30X-SDI/NDI cameras running firmware before 6.3.40. The camera does not sufficiently validate the ntp_addr configuration value, which can lead to arbitrary command execution. CISA lists it as known to be exploited, and chained with CVE-2024-8956 it allows remote, unauthenticated command execution.

Impact

On its own, an attacker needs network access and high privileges to run arbitrary OS commands when ntp_client starts. When chained with CVE-2024-8956, a remote attacker needs no authentication. CISA rates the technical impact as total, meaning full control of the camera. CISA does not consider it automatable. Successful exploitation affects confidentiality, integrity and availability of the device. Attackers are known to use this vulnerability.

Who is affected

The CVE record lists PTZOptics PT30X-SDI and PTZOptics PT30X-NDI cameras with firmware versions before 6.3.40 as affected. Firmware 6.3.40 contains the fix for both models. The version data comes from the CVE record published by its CNA, VulnCheck.

Written with AI from the data on this page and checked against it automatically.

Official description

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

CISA required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.

CISA notes

Affected and fixed versions

From the CVE record published by the vendor or CVE numbering authority.

  • PTZOptics PT30X-SDI
    Affected
    • < 6.3.40
    Fixed in
    • 6.3.40
  • PTZOptics PT30X-NDI
    Affected
    • < 6.3.40
    Fixed in
    • 6.3.40

How to fix it

  • Update to the fixed version for your product:
    • PTZOptics PT30X-SDI: 6.3.40
    • PTZOptics PT30X-NDI: 6.3.40
  • Vendor advisory: ptzoptics.com/firmware-changelog
  • CISA's deadline for US federal agencies: 2024-11-25 (passed) – a useful benchmark for everyone else, too.

What to do

  1. Update PT30X-SDI and PT30X-NDI cameras to firmware 6.3.40 or later.
  2. Also address CVE-2024-8956, since chaining the two removes the need for authentication.
  3. Keep camera management interfaces off the internet and restrict access to trusted networks.
  4. Review camera configuration, including the NTP server setting, for unexpected values and check devices for signs of compromise.
  5. Follow the vendor advisory; if mitigations are unavailable, CISA requires discontinuing use of the product.

Written with AI from the data on this page and checked against it automatically.

CISA's assessment (SSVC)

Exploitation
Exploited in the wild
Automatable
No – each attack needs manual steps
Technical impact
Total – full control of the component or total information disclosure

Weakness: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Questions about CVE-2024-8957

Is this vulnerability being exploited?
Yes. CISA added CVE-2024-8957 to its Known Exploited Vulnerabilities catalog on 2024-11-04, with a US federal due date of 2024-11-25. Whether it is used in ransomware campaigns is unknown.
Does an attacker need credentials?
Exploiting this flaw alone requires high privileges. However, when chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected cameras.
Which firmware fixes the issue?
Firmware 6.3.40 fixes the vulnerability for both the PTZOptics PT30X-SDI and PTZOptics PT30X-NDI models.

Written with AI from the data on this page and checked against it automatically.

References

Data: CISA Known Exploited Vulnerabilities (public domain) · CVE Program records incl. CISA ADP enrichment · OSV.dev (CC BY 4.0) incl. Ubuntu and Debian security data · FIRST EPSS · endoflife.date. Updated automatically – facts last changed 2026-11-21. Always confirm with the vendor's or distribution's advisory before patching.