Skip to content
Server Security Center
KEVcritical9.8

CVE-2025-67038: Lantronix EDS5000 Code Injection

Lantronix EDS5000 · listed in the CISA catalog of actively exploited vulnerabilities since 2026-06-23.

CVSS v3.1 (CVE record)
9.8
critical
EPSS (exploit probability, 30 days)
21%
higher than 97.6% of all CVEs
Added to CISA KEV
2026-06-23
US federal due date 2026-06-26
Automatable (CISA SSVC)
yes
technical impact: total

CVE-2025-67038 explained

CVE-2025-67038 is an OS command injection flaw (CWE-78) in the HTTP RPC module of Lantronix EDS5000 and several related Lantronix series. When authentication fails, the username is placed into a logging shell command without sanitization, so injected commands run as root. CISA lists it as known exploited, which makes it a priority for ICS environments.

Impact

An unauthenticated attacker with network access to the HTTP RPC interface can run arbitrary OS commands with root privileges. No user interaction is needed. CISA rates it as automatable with total technical impact, meaning attackers can exploit it at scale and take full control of the device. Confidentiality, integrity and availability are all at high risk. CISA's catalog confirms exploitation in the wild. Ransomware use is listed as unknown.

Who is affected

Lantronix EDS5000 series versions ≤ 2.1.0.0R3 are affected, and the CVE record names no fixed version for it. Lantronix G520 series and X300 series before 2.6.0.4R6 are affected and fixed in 2.6.0.4R6. Lantronix E210 series and E220 series before 3.21.0.0R1 are affected and fixed in 3.21.0.0R1.

Written with AI from the data on this page and checked against it automatically.

Official description

An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization.

This allow attackers to inject arbitrary OS commands into the username parameter. Injected commands are executed with root privileges.

CISA required action: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk guidance and CISA’s “Forensics Triage Requirements”. Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

CISA notes

Affected and fixed versions

From the CVE record published by the vendor or CVE numbering authority.

  • Lantronix EDS5000 series
    Affected
    • ≤ 2.1.0.0R3
    Fixed in
    not stated
  • Lantronix G520 series
    Affected
    • < 2.6.0.4R6
    Fixed in
    • 2.6.0.4R6
  • Lantronix X300 series
    Affected
    • < 2.6.0.4R6
    Fixed in
    • 2.6.0.4R6
  • Lantronix E210 series
    Affected
    • < 3.21.0.0R1
    Fixed in
    • 3.21.0.0R1
  • Lantronix E220 series
    Affected
    • < 3.21.0.0R1
    Fixed in
    • 3.21.0.0R1

How to fix it

  • Update to the fixed version for your product:
    • Lantronix G520 series: 2.6.0.4R6
    • Lantronix X300 series: 2.6.0.4R6
    • Lantronix E210 series: 3.21.0.0R1
    • Lantronix E220 series: 3.21.0.0R1
    For the other affected products the CVE record names no fixed version – see the table and the vendor advisory.
  • Vendor advisory: lantronix.com/technical-support/security-updates/vulnerab…
  • CISA's deadline for US federal agencies: 2026-06-26 (passed) – a useful benchmark for everyone else, too.

Vendor solution:

What to do

  1. Update G520 and X300 series devices to 2.6.0.4R6 or later.
  2. Update E210 and E220 series devices to 3.21.0.0R1 or later.
  3. For EDS5000 series, follow the Lantronix advisory and apply the vendor's mitigations.
  4. Block internet access to device web and RPC interfaces and restrict them to trusted management networks.
  5. Check devices for signs of compromise, following CISA's forensics triage requirements.
  6. Discontinue use of any device where mitigations are unavailable, as CISA's required action states.

The CVE record names no fixed version for the EDS5000 series. Check the Lantronix advisory for updates or mitigations and apply them. CISA requires applying vendor mitigations and discontinuing use if none are available. Until then, keep the device off the internet, limit HTTP access to trusted hosts, and check for signs of compromise.

Written with AI from the data on this page and checked against it automatically.

CISA's assessment (SSVC)

Exploitation
Exploited in the wild
Automatable
Yes – attackers can automate it at scale
Technical impact
Total – full control of the component or total information disclosure

Weakness: CWE-78

Questions about CVE-2025-67038

Do attackers need credentials to exploit CVE-2025-67038?
No. The flaw is triggered through the username in a failed login, so no privileges or user interaction are required. Network access to the HTTP RPC interface is enough.
Is this vulnerability being exploited?
Yes. CISA added it to its Known Exploited Vulnerabilities catalog on 2026-06-23, with a US federal due date of 2026-06-26. Ransomware use is listed as unknown.
Which versions fix the issue?
G520 and X300 series are fixed in 2.6.0.4R6. E210 and E220 series are fixed in 3.21.0.0R1. The CVE record names no fixed version for the EDS5000 series. Consult the vendor advisory for that product.

Written with AI from the data on this page and checked against it automatically.

References

Data: CISA Known Exploited Vulnerabilities (public domain) · CVE Program records incl. CISA ADP enrichment · OSV.dev (CC BY 4.0) incl. Ubuntu and Debian security data · FIRST EPSS · endoflife.date. Updated automatically – facts last changed 2026-11-21. Always confirm with the vendor's or distribution's advisory before patching.